コンテンツメニュー

Experimental Study on the Micro Cyclone Separator : Flow Pattern in the Cyclone

Memoirs of the Faculty of Engineering, Yamaguchi University Volume 17 Issue 1 Page 35-40
published_at 1966
KJ00000155551.pdf
[fulltext] 786 KB
Title
超小型サイクロン分離器に関する実験的研究 (内部の流動状態について)
Experimental Study on the Micro Cyclone Separator : Flow Pattern in the Cyclone
Creators Ueoka Yutaka
Creators Ueno Goro
Creators Kawakami Yasushi
Source Identifiers
The flow pattern and the pressure loss of the micro cyclone separator (diameter D=10mm~30mm) have been studied experimentally. The results obtained are as followes : i) The relations between the inlet air velocity V and the pressure loss in the various cyclones shaped such as Fig. 1,are showen in Fig. 2. ii) The pressure loss in the cyclone (Fig. 1,type II) varies completly with the change of cyclone length L, and it is shown in Fig. 5. iii) The static pressure distribution at the inside wall of the cyclone (Fig. 2,typeII) is illustrated in Fig. 6. iv) The pattern of collected talc dust on the inside wall of the cyclone is photographed such as Fig. 8. The pressure loss is minimum in the type II cyclone and it increases as the dimension of the cyclone diameter D. In case of type II, the pressure loss has the sharp peaks at the cyclone length of 2.0D, 5.5D, 9.5D. This strange phenomenon will be due to the efflux of spiral-shaped vortex core from the outlet. The distribution of the static pressure and the talc adhesion on the inside wall reveal obviously the details of the flow pattern in a cyclone.
Subjects
機械工学 ( Other)
Languages jpn
Resource Type departmental bulletin paper
Publishers 山口大学工学部
Date Issued 1966
File Version Version of Record
Access Rights open access
Relations
[ISSN]0372-7661
[NCID]AN00244228
Schools 工学部